- #HP DMI TOOL FEATURE BYTE DRIVERS#
- #HP DMI TOOL FEATURE BYTE SOFTWARE#
- #HP DMI TOOL FEATURE BYTE CODE#
- #HP DMI TOOL FEATURE BYTE PC#
The new FlexBuild FeatureByte label will be in the following format: 12 FlexBuild Options BID=51NAheBLU2,51NAheBLU1 FeatureByte=0qr121100. The RIN moves from the agency label, where it was called the SW BOM, to the new Feature Byte label. This will enable Field Engineer to know when to use legacy repair process & when to use FlexBuild repair process for installed base. This will help distinguish Legacy-Units from FlexBuild-units. ** The Legacy FeatureBytes will NOT be printed on the AGENCY label for units made w/ FlexBuild process. This label is in addition to the existing agency label.Īdditionally, this information can be found on Traceability for CTO units.Ĭontents of Agency & FlexBuild Printed Labels Item NameĬPC Flex-Unit Repair & Recovery Process FeatureBytes fixed length (10 bytes) FlexBuild FeatureBytes
#HP DMI TOOL FEATURE BYTE CODE#
Is visible to 3rd party ASP repair engineersĬontains BID (Build ID) information, legacy feature byte code and flexbuild feature byte information Is stored on a printed label affixed on the bottom of the unit’s chassis Needed Information DMI information is provided for each unit, whether it is a retail unit or a CTO unit. Only certain units in North America will be Flex-Units for Spring 05, all WW units will be Flex-Units beginning Spring Refresh 05. The only difference between the two types of units is with the feature bytes, which will be explained later. It will not support units before this time. Supplemental CD/DVD can be maximum one CD or DVD oĭepends on quantity and size of updates & TTM SWįlexBuild : RECOVERY CONCEPTS Build Type > Base Build Factory Build-IDįlex-Unit Repair Process The new tattoo, called cPC-DMI, will support both Flex-Units and Legacy-Units starting with Spring 05.
#HP DMI TOOL FEATURE BYTE DRIVERS#
These updates are exclusive of CPE updatesĪll TTM drivers and non-huge apps released mid-cycle during a major business cycle Supplemental CD/DVD can or will contain oĪLL accumulated post-PR factory updates (formerly aka factory patches) May requires the need to send a Supplemental CD/DVD Takes > 120 minutes to re-build the image Is essentially a Mini FlexBuild Process on the CD/DVD set Is sent by Support Organization: sent if and when replacing failed HDD Is 1 CD/DVD set per Language-Country Set-OS-Brand combo
Is the result of the FlexBuild process, the bits have been “cooked”.
#HP DMI TOOL FEATURE BYTE SOFTWARE#
Is quicker when recovering from CD as it only has the software for that model FlexBuild Process involves a set of roles, tools and procedures.įor efficient, flexible, timely and automatic generation of per retail-sku and per cto-unit sw build image on the factory floorįor enabling re-generation of sw image in field from Support-sent FlexRecovery CD/DVD set comprising a set of Base Recovery CDs/DVDs and a Supplemental CD/DVD Flex-Units are PC’s which have the software build loaded based on the FlexBuild process.
SAMPLE PICTURES.16īeginning with the Spring-Refresh 05 cycle, there is a new tattoo program being implemented to coincide with the introduction of Flex-Units. 10įLEXBUILD & LEGACY SW BUILDS TERMS & GLOSSARY. 2 CONTENTS OF AGENCY & FLEXBUILD PRINTED LABELS. 1 1.1 1.2įLEX-UNIT REPAIR PROCESS.2 2.1 2.2 2.3ĬUSTOMER CREATED RECOVERY CD/DVD SET.1 SUPPORT-SENT RECOVERY CD/DVD SET. Use or disclosure without written permission of an officer of HP is expressly forbidden.įLEX-UNIT RECOVERY. This document contains information proprietary to Hewlett-Packard. HP CONFIDENTIAL Hewlett-Packard Confidential-Need to Know RequiredĬopyright © 2004 Hewlett-Packard Company.
#HP DMI TOOL FEATURE BYTE PC#
CPC Flex-Unit Repair & Recovery Updated for VistaĬonsumer PC GBU Hewlett-Packard Company, Cupertino, CA